Condominium Owners and the Board of Directors that are charged with guiding and overseeing a window replacement project are not always up to speed with the quality control measures that should be specified on a replacement project to ensure the best results.
If you are on the board of a Condominium Association or are a concerned owner that knows your building is going to be renovated, make certain that third party testing is going to be included on your project.
Demand it. You'll be living with the results. The value of your unit depends upon it.
For more information on what needs to be included, contact Recon Independent Assessments. We will review your project specs prior to the project being put out to bid to help ensure your investment is protected.
866-584-6868
Recon Independent Assessments - Building Envelope Consultants, Qualified Third Party Testing Agency, Expert Litigation Support
Thursday, December 15, 2011
Monday, December 12, 2011
Multi-Family Residential & Student Housing
Recon Independent Assessments has been minding the store so to speak, taking care of projects here closer to home over the past days.
A Multi-Family Apartment project in a retirement community was successfully tested using ASTM E-1105 Method B test proceedures.
A Student Housing project will recieve the first round of testing in the coming days as the project looks to ensure the installation of windows is going well before getting rolling. Taking the time to validate methods and workmanship early can save money, time and reputations.
A Multi-Family Apartment project in a retirement community was successfully tested using ASTM E-1105 Method B test proceedures.
A Student Housing project will recieve the first round of testing in the coming days as the project looks to ensure the installation of windows is going well before getting rolling. Taking the time to validate methods and workmanship early can save money, time and reputations.
Tuesday, December 6, 2011
Florida Field Testing
In response to many clients asking for services beyond Field Testing Windows, Storefront, Curtain Wall and Skylights for Water Penetration Resistance (ASTM E 1105,AAMA 502, AAMA 503), a spin off company was formed just a little over a year ago to meet those needs.
Florida Field Testing, LLC
One of the services FFT provides is Third Party Testing of concrete slabs for moisture content.
For more information regarding FFT's RH Probe testing for concrete slabs, CLICK HERE
Florida Field Testing, LLC
One of the services FFT provides is Third Party Testing of concrete slabs for moisture content.
For more information regarding FFT's RH Probe testing for concrete slabs, CLICK HERE
Sunday, December 4, 2011
Nationwide Third Party Window Testing - AAMA 502 & 503 - AAMA 501.2 - ASTM E 1105 & E 783
Recon Independent Assessments, LLC is set to finish 2011 in strong fashion. As we look back at the year in review, we are pleased to have been involved in many projects throughout the entire country. Field testing newly installed windows, curtain wall, skylights and storefronts was provided from the east coast to the pacific rim.
Expert legal services are ongoing in the mid west.
Building envelope consulting services increased in 2011 as well.
Leak detection and forensic cause and origin testing increased over the past year, allowing Recon to provide many happy clients with solutions that had been eluding them.
Our total commitment to quality, affordable consulting and testing services should continue to spur growth in 2012.
We hope to see you on your project soon.
Contact us to learn how we may be of service to you:
866-584-6868
Additional Construction Materials Testing services are available through Florida Field Testing
Expert legal services are ongoing in the mid west.
Building envelope consulting services increased in 2011 as well.
Leak detection and forensic cause and origin testing increased over the past year, allowing Recon to provide many happy clients with solutions that had been eluding them.
Our total commitment to quality, affordable consulting and testing services should continue to spur growth in 2012.
We hope to see you on your project soon.
Contact us to learn how we may be of service to you:
866-584-6868
Additional Construction Materials Testing services are available through Florida Field Testing
Friday, November 11, 2011
Skylight Replacement Field Quality Control
Recon provided field testing services at University of Buffalo to ensure that the replacement of skylights was successful.
AAMA 501.2 Field Quality Control Check procedures were used to evaluate the success of the installation.
Recon is available to complete testing on your project, wherever it may be. Contact us to discuss how our service and pricing will best serve your needs for a Qualified Third Party Field Testing Agency.
866-584-6868
AAMA 501.2 Field Quality Control Check procedures were used to evaluate the success of the installation.
Recon is available to complete testing on your project, wherever it may be. Contact us to discuss how our service and pricing will best serve your needs for a Qualified Third Party Field Testing Agency.
866-584-6868
Subscribe to:
Posts (Atom)