Tuesday, July 1, 2014

Building Envelope QC, Window Testing, Sealant Pull Tests, Field Roof Uplift Testing & GPR - Recon and Florida Field Testing Has Been Busy

Multi-Family Field Quality Control Testing

Walker & Co ASTM E-1105



Walker & Co ASTM E-1105



Walker & Co ASTM E-1105

New Construction HS Expansion

Wharton Smith ASTM E-1105



Wharton Smith ASTM E-1105


Florida Field Testing, LLC Providing
GPR to Locate Rebar in Footer

Florida Construction GPR Services



Florida Construction GPR Services



Florida Construction GPR Services

On the Way to Our Next Project

Recon Provides Services for Building Envelope Nationwide

Field Testing RTS Bus Maintenance Facility

Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105

Contact Us at 407-948-4983 to Discuss your Building Envelope or Testing Needs 

Friday, April 18, 2014

Building Envelope Nearing Completion

Recon Independent Assessments has been involved in the project from Design Review through Construction. By providing periodic Quality Control Visits and Consulting through the building process, Recon helped head off problems and identified areas that required special attention to ensure a watertight delivery.

Components covered included curtain wall, composite metal panels, roofing, skylights, terra cotta facade and sealants.

Its always a pleasure seeing a building take shape and march along towards completion.



Recon Independent Assessments provides Building Envelope Consulting and Field Testing throughout the United States.

Contact us today to discover how our experience can benefit your next project.

407-948-4983

Wednesday, August 15, 2012

Baltimore Building Envelope Review and Window Testing









Recon is providing building envelope review and consulting on a hospital renovation as well as field quality control testing of installed windows and curtain wall on an adjacent MOB in the Baltimore area.

Call 866-584-6868 to discuss how Recon can provide your project with similar services.







Monday, May 14, 2012

Liquid Applied Vapor Permeable Air Barrier Testing ASTM E 783

Moultrie Technical College is expanding their campus.

Recon Independent Assessments was selected to provide field testing on the project for building envelope related trades.

An initial test of the vapor permeable air barrier was conducted using an ASTM E 783 field test for air infiltration rate.  The application was successful.




Additional field testing of the liquid applied vapor barrier as well as field testing of the installed fenestration is scheduled in the future.

To Schedule your project with Recon Independent Assessments:

866-584-6868

Sunday, May 13, 2012

Storefront and Curtain Wall Systems Examined Via ASTM e 1105 & AAMA 501.2

Recon Independent Assessments was selected to provide testing as a Qualified Third Party Testing Agency on a Jacksonville, FL high school construction project.

Robert E. Lee High School

Test Early in The Project

Storefront Examination for
 Water Penetration
Resistance

Critical details like corners and wall interfaces
are best tested to
ensure the envelope is
watertight. 

Curtain Wall Field Testing
866-584-6868

AAMA 501.2 at sill to slab interface

Discovering problems during
the project saves time and expense
later after interior finishes
are installed.


Project specifications require field quality control testing.  The specifications include AAMA 501.2 and ASTM E 1105 procedures to evaluate the newly installed fenestration for water penetration resistance.











 866-584-6868

Wednesday, April 4, 2012

Curtain Wall Testing Completed at University of North Florida

As a Qualified Third Party Testing Agency, Recon provided field testing services on the Student Wellness Center at UNF to ensure the water penetration resistance of the completed curtain wall facades.  A random sampling of curtain wall sections were tested to provide quality control on the project.

Remaining building envelope testing will include a field quality control check (AAMA 501.2) of a sizable portion of the metal panel facade.

Recon Independent Assessments provides professional testing services, to learn more about how we can help on your next project, call us:

866-584-6868

Nozzle Test
Field Quality Control's Easy Button:  Recon Independent Assessments

Qualified Third Party Testing ASTM E-1105 & AAMA 501.2

Recon
Stand behind every window that is installed on your project, field test the installation to ensure water penetration resistance.
Recon Independent Assessments provides testing on site for water penetration resistance and air infiltration.  ASTM & AAMA test standards are followed to ensure a quality project results from the work performed.

Call anytime: 866-584-6868

We're ready to show you how easy testing can be.

Sunday, January 1, 2012

Recon Independent Qualified Third Party Testing Agency

Recon Independent Assessments, LLC is ready to provide your project the best value third party field quality control testing available.

AAMA 501.2, AAMA 502, AAMA 503, ASTM E 1105 and ASTM E 783 are available on your jobsite anywhere in the United States and beyond.

We're confident that we've developed the right balance of services vs. cost,  sales increased in 2011 by over 70%.

Join us in 2012 by having Recon Independent Assessments provide the building envelope review and testing on your project and you will learn how well testing can be performed without busting the budget.

From the eastern seaboard to the pacific rim, Recon delivered testing services on time and in some cases, under budget in 2011.  Our goal is to build on last year's success, we hope your project will be one of those trusted to our capabilities and judgement.

Call today to be introduced to the Fastest Growing Qualified Third Party Testing Agency in America:

866-584-6868

Thursday, December 15, 2011

Condo Window Replacement Quality Control

Condominium Owners and the Board of Directors that are charged with guiding and overseeing a window replacement project are not always up to speed with the quality control measures that should be specified on a replacement project to ensure the best results.

If you are on the board of a Condominium Association or are a concerned owner that knows your building is going to be renovated, make certain that third party testing is going to be included on your project.

Demand it.  You'll be living with the results.  The value of your unit depends upon it.

For more information on what needs to be included, contact Recon Independent Assessments.  We will review your project specs prior to the project being put out to bid to help ensure your investment is protected.

866-584-6868

Sunday, December 4, 2011

Nationwide Third Party Window Testing - AAMA 502 & 503 - AAMA 501.2 - ASTM E 1105 & E 783

Recon Independent Assessments, LLC is set to finish 2011 in strong fashion. As we look back at the year in review, we are pleased to have been involved in many projects throughout the entire country. Field testing newly installed windows, curtain wall, skylights and storefronts was provided from the east coast to the pacific rim.

Expert legal services are ongoing in the mid west.

Building envelope consulting services increased in 2011 as well.

Leak detection and forensic cause and origin testing increased over the past year, allowing Recon to provide many happy clients with solutions that had been eluding them.

Our total commitment to quality, affordable consulting and testing services should continue to spur growth in 2012.

We hope to see you on your project soon.

Contact us to learn how we may be of service to you:

866-584-6868

 Additional Construction Materials Testing services are available through Florida Field Testing

Friday, November 11, 2011

Skylight Replacement Field Quality Control

Recon provided field testing services at University of Buffalo to ensure that the replacement of skylights was successful.

AAMA 501.2 Field Quality Control Check procedures were used to evaluate the success of the installation.

Recon is available to complete testing on your project, wherever it may be.  Contact us to discuss how our service and pricing will best serve your needs for a Qualified Third Party Field Testing Agency.

866-584-6868

Monday, October 17, 2011

Third Party Field Quality Control Testing & Consulting

Recon Independent Assessments is called on often to help locate latent issues in the building envelope that have allowed for water penetration.

For the most part, sealants often play the dominant role in being the proximate cause of an envelope failure.

Once the  possible source(s) have been identified, a remedial plan must be executed to repair the breached envelope.

After the repair, the most critical part of the remedial plan should take place, re-testing the subject areas to confirm the repair worked and the suspected source was the only source.  Often times multiple sources can only be determined as each overlying cause is repaired.

Recon uses a systematic, thoughtful and purposed approach to ongoing intrusion issues. By not rule in or out any possibility we feel confident that finding the source of failure can be achieved. We approach the building envelope suspecting anything and everything has failed and develop an investigative process that requires each part of the facade to perform.

Available Nationwide:  866-584-6868

Wednesday, October 12, 2011

Baltimore Healthcare Project


Orlando School Project

Norfolk Military Project

Jacksonville University Project

Hawaii Community College Project

Washington DC Commercial Office Project

ASTM E 1105 Field Quality Control

AAMA 502 Field Quality Control


The Industry Leader For Independent Third Party Testing

• ASTM E 1105 Field Test for Water Penetration / Static Pressure.
• ASTM E 783 Field Test for Air Infiltration.
• AAMA 501.2 Field Check Metal Curtain Walls / Water Leakage.
• AAMA 501.3 Field Water Test- Static Method.
• AAMA 502 Field Test - Windows.
• AAMA 503 Field Test - Curtain Walls.


We take a team approach to advising clients on the
right strategies to develop a Sound Envelope and
Sensible Quality Control plans.

866 - 584 - 6868

Monday, September 26, 2011

Recon Independent Assessments Provides ASTM & AAMA Window Testing Anywhere

ASTM E 1105 Testing by Recon Independent Assessments



Recon Independent Assessments is providing Division 8 Field Quality Control Testing on a community college campus this week in Hawaii.

Our reputation for reasonable pricing and quality testing services leads us to yet another opportunity.

In addition to the engagement that we have to provide ASTM E 1105 testing on the island, we will be visiting another site to provide a pre-bid walk though for yet another.

Wherever your project happens to be, Recon can be there.

Call us anytime 866-584-6868

Thursday, August 25, 2011

Baltimore ASTM E 783 & ASTM E 1105 Window Testing


Recon Independent Assessments is returning to Baltimore to complete field testing on newly installed windows on the new construction project at Sinai Hospital.

If your project is in the Baltimore - Washington, DC area required a Qualified Third Party Testing Agency for field testing, we are happy to provide you with a proposal.  If time allows, we can potentially visit your site early next week.

Questions or Proposal Requests: 866-584-6868

Wednesday, August 3, 2011

Water Penetration Field Testing - ASTM E 1105 or Mother Nature

Wind & Rain Are in the Forecast!!
If you had your choice, would you rather learn of problems with installed fenestration or perimeter sealants while you're project is being built or by phone call from an owner after a storm?

Recon Independent Assessments is your link to quality field testing services:  866-584-6868

Tuesday, July 19, 2011

Coastal Healthcare Project AAMA 501.2 & ASTM E 1105

Two days of testing along the coast of Georgia involved providing AAMA 501.2 Field Quality Control Checks on multiple windows on a health care facility renovation project.

Additional windows were tested to the ASTM E 1105 standard.

Field Testing Division 8 work is always a good idea, along the coast, its imperative.  Mother Nature will surely provide opportunities to test a system, so get out in front of her and test during construction to ensure the owner has a watertight building envelope before your reputation is tested too.

Saturday, July 9, 2011

Field Testing of Installed Windows Made Easy

Recon Independent Assessments makes field testing performed under the Field Quality Control section of Division 8 an easy affair.

AAMA 501.2, AAMA 502,AMMA 503or ASTM E1105 Standard?  No Problem

ASTM E 1105 Test Procedure
Available Nationwide:

866-584-6868