Building Envelope QC, Window Testing, Sealant Pull Tests, Field Roof Uplift Testing & GPR - Recon and Florida Field Testing Has Been Busy

Multi-Family Field Quality Control Testing

Walker & Co ASTM E-1105



Walker & Co ASTM E-1105



Walker & Co ASTM E-1105

New Construction HS Expansion

Wharton Smith ASTM E-1105



Wharton Smith ASTM E-1105


Florida Field Testing, LLC Providing
GPR to Locate Rebar in Footer

Florida Construction GPR Services



Florida Construction GPR Services



Florida Construction GPR Services

On the Way to Our Next Project

Recon Provides Services for Building Envelope Nationwide

Field Testing RTS Bus Maintenance Facility

Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105



Charles Perry Partners, Inc. Field Testing ASTM E-1105

Contact Us at 407-948-4983 to Discuss your Building Envelope or Testing Needs 

Thursday, January 13, 2011

RMS Cat Model Revision May Cause Homeowners Rate Shift | PropertyCasualty360

Ultimately, when windows and roofs fail under the load of a storm event, insurance steps in to restore the subject property to pre-loss condition.

Preparing for an event by ensuring everything that could be done to prevent water penetration from wind driven rain is essential.

Field testing installed fenestration in newly constructed buildings has been proven to be a plus when faced with actual weather events that test the system to it's design loads.

A robust field quality control specification that demands excellence is the first defense in making sure your buildings weather the storm.



Conventional wisdom has always been to test along the coast, perhaps its time for Spec Writers to acknowledge that risks from wind driven rain exist inland as well. The Article Linked below clearly shows that the folks that ultimately pick up the tab have recognized that fact.

RMS Cat Model Revision May Cause Homeowners Rate Shift PropertyCasualty360

Now read the Linked Article below to see how Field Testing using the ASTM E 1105 lead to great results for a resort while others suffered lost revenue due to damage.

Print it and share with your QC Team and Spec Writers:

http://www.peci.org/ncbc/proceedings/2005/16_Parzych_NCBC2005.pdf

Monday, October 19, 2009

The Question Most Often Asked When Water Penetration Field Testing Installed Windows

How much wind (fast) does that field test simulate?



Suprisingly little when you think about it. If a failure is observed in field testing, it's usually well below the design pressure classification of the installed product.

Think about it, well below.

Field testing is a great tool to ensure your skilled tradesmen are paying attention to detail and remain focused on the project goal of delivering a watertight envelope.

Test early & often; make sure when the wind does blow, your reputation for quality construction is tied down nicely.

info@reconwindowtesting.com for any questions you might have regarding specifications on your project.

Thursday, October 15, 2009

Wednesday, May 20, 2009

Moisture Intrusion Investigation

Recon Independent Assessments helps put and end to images like these:







Recon Independent Assessments prefers to be on the proactive side of the equation providing validation testing during the construction of a building. Unfortunately, even where testing takes place (not every opening is tested), there may be an occassional water intrusion issue after building turnover.



Recon conducts water intrusion investigations wherever your needs require . Contact us today to discuss how we may be able to assist you.