Wednesday, January 7, 2015

Water Intrusion Solutions

Recon Independent Assessments has a history of solving problems where water intrusion has plagued a building and attempts to repair them has been unsuccessful.  One of the main issues we encounter is where the approach to the problem is one that begins with a presumption.

"It has to be "'xyz'…"

Recon approaches all of its projects from the standpoint of ignorance of the issue.  Essentially, we don't know what we don't know.  We require testing and examination reveal the issue in black and white.

Building Envelope Consulting Dry Building
Thermal Imaging Used To Determine Anomalies For Further Investigation

Dry Building Recon Building Envelope Consultants
Examination of Penetrations


Time is always of essence for the client, but we don't rush to conclusions.  Its really that simple.

Slow and steady is how we've established our reputation of being able to uncover the tough to locate intrusion points.

If you have a problem, big or small, we're ready for the challenge.

Call us today to discuss your building envelope needs and a proposal of cost.

407-948-4983

Tuesday, January 6, 2015

Building A Better Envelope In 2015



Recon Independent Assessments, LLC

866-584-6868 


Recon Independent Assessments finished off the last quarter of 2014 strong, helping multiple project teams with anything from providing bid information, testing newly installed windows, curtain wall and storefront to providing investigation and design assistance on a structure that has been plagued with water intrusion issues for years.  While others had conducted studies and implemented "solutions", we are able to definitively identify the issues that were continuing to allow for water intrusion and are currently involved in the design fixes to remedy the issues.

Recon Independent Assessments has been focused on providing superior service to its clients over the years and 2014 was no different.  Our approach, which involves principals on-site on all of our projects ensures that the most experience can be brought to bear to flesh out the issues or to conduct testing seamlessly.

If you're experiencing problems with a building that requires identification of all of the issues the first time, give us a call.

We are determined to continue or successful ways in 2015, we hope you'll allow us to join you in yours.

While most of our projects are generated by repeat clients or their referrals, we always welcome new ones.

Call us to discuss your project needs and to learn how affordable our rates are.  As a Small Business our low overhead translates into savings on your project.

Building Envelope Consultants
AAMA 501.2 Field Quality Control Check

Building Envelope Consulting
Building Envelope Examination & QC Review

Building Envelope Consultants
TPO Roof Installation QC Examination

Building Envelope Consultants
EIFS Review & Quality Control Examination


See you on-site!

Recon Independent Assessments, LLC

407-948-4983

Thursday, October 15, 2009

Tuesday, June 2, 2009

Field Quality Control Matters

Recon Independent Assessments has been providing on site field testing services for water penetration (ASTM E 1105) and air infiltration (ASTM E 783) for the following contractors. We look forward to joining your team as well.











We hope to join your team too. Send us an invite, you wont be disappointed!





Tuesday, May 19, 2009

A Healthy Dose of Subtropical Rain is Falling - Did Your Project Get The ASTM E 1105 Testing It Deserved?

Much like in 2001 with Tropical Storm Allison in Texas, there is a Subtropical System making an pre-season visit; this time in Georgia and Florida.





Recon Independent Assessments knows that planning and execution are the key to providing a watertight building envelope on a new structure. Several projects that we've recently provided Field Quality Control Testing on are getting a real world test as Mother Nature sends the coast of Florida and Georgia an early tropical season low pressure system. There is no doubt that some folks are resting a bit easier knowing that the recently installed fenestration and glazing in their projects has been evaluated for field performance via the ASTM E 1105.




Contact Recon Independent Assessments today to allow us to bring you quality ASTM Field Testing that will benefit your project.





Get a Cost Effective Field Testing Proposal today: info@GoRecon.net








Wednesday, May 13, 2009

Recon Independent Assessments provides quality and value with field testing services using ASTM E 1105 test proceedures.

A calibrated spray rack is placed on the building exterior to simulate rain.

A vaccum chamber is placed on the interior side of the opening and negative pressure is maintained at a prescribed level to test the opening and installed assembly interface.

The negative pressure is maintained and monitored throughout the test cycle.

Visual inspection of the test subject is maintained to check for evidence of water penetration.

Contact Recon Independent Assessments to Request a Proposal for Testing on your Project:

info@GoRecon.net

Your Project's Success Is Our Goal!

Wednesday, March 25, 2009

All Roads Lead Back to The ASTM E1105

ASTM E1105

Significance and Use

This test method is a standard procedure for determining the resistance to water penetration under uniform or cyclic static air pressure differences of installed exterior windows, skylights, curtain walls, and doors. The air-pressure differences acting across a building envelope vary greatly. These factors should be considered fully prior to specifying the test pressure difference to be used.

Note 1—In applying the results of tests by this test method, note that the performance of a wall or its components, or both, may be a function of proper installation and adjustment. In service, the performance will also depend on the rigidity of supporting construction and on the resistance of components to deterioration by various causes, vibration, thermal expansion and contraction, and so forth. It is difficult to simulate the identical complex wetting conditions that can be encountered in service, with large wind-blown water drops, increasing water drop impact pressures with increasing wind velocity, and lateral or upward moving air and water. Some designs are more sensitive than others to this upward moving water.

Note 2—This test method does not identify unobservable liquid water which may penetrate into the test specimen.

Laboratory tests are designed to give an indication of the performance of an assembly. Field performance may vary from laboratory performance since the supporting structure for the test specimen, methods of mounting, and sealing in the laboratory can only simulate the actual conditions that will exist in the building. Shipping, handling, installation, acts of subsequent trades, aging, and other environmental conditions all may have an adverse effect upon the performance of the installed product. This field test procedure provides a means for determining the performance of a product once installed in the building.

The field test may be made at the time the window, skylight, curtain-wall, or door assemblies are initially installed and before the interior of the building is finished. At this time, it is generally easier to check the interior surfaces of the assemblies for water penetration and to identify the points of penetration. The major advantage of testing when assemblies are initially installed is that errors in fabrication or installation can be readily discovered and corrections made before the entire wall with its component assemblies is completed at which time the expense of corrective work may be increased many times.

The field test may also be made after the building is completed and in service to determine whether or not reported leakage problems are due to the failure of the installed assemblies to resist water penetration at the specified static air pressure difference. Generally it is possible to conduct tests on window, skylight, and door assemblies without too much difficulty, and to identify sources of leakage. A curtain-wall assembly, on the other hand, may not be accessible from the inside without the removal of interior finished walls and ceilings. Even with removal of interior walls and ceilings, it may not be possible to observe curtain-wall surfaces behind spandrel beams. The feasibility of conducting a meaningful static air pressure difference water penetration test on an in-service building must be carefully evaluated before being specified.
Weather conditions can affect the static air pressure difference measurements. If wind gusting causes pressure fluctuation to exceed ±10 % from the specified test pressure, the test should not be conducted.

Generally it is more convenient to use an interior mounted pressure chamber from which air is exhausted to obtain a lower pressure on the interior surface of the specimen. A calibrated rack of nozzles is then used to spray water at the proper rate on the exterior surface. Under circumstances where it is desirable to use an exterior-mounted pressure chamber, the spray rack must be located in the pressure chamber and air supplied to maintain a higher pressure on the exterior surface. Exterior chambers are difficult to attach readily and seal to exterior surfaces.

Even though the equipment requirements are similar, this procedure is not intended to measure air infiltration because of the difficulty of isolating the component air leakage from the extraneous leakage through weep holes, mullion joints, trim, or other surrounding materials.

Tuesday, March 10, 2009

Quality Control: Window Testing Presentation & Discussion





Recon Independent Assessments travelled to Jacksonville, Florida to provide a short seminar regarding window testing to staff at Haskell. The differences between AAMA and ASTM specifications, the equipment required to test accurately, as well as a demonstration on a portable mock-up was provided for the group of approximately 30 construction professionals in attendence.

Recon loves the opportunity to participate with clients in a training environment. Contact us today to schedule a training date with us.

Wednesday, March 4, 2009

Why Field Test Installed Windows? They Passed The Lab...

Testing Requirements Ensure Design Goals Are Met

There are many reasons to verify the installed performance of windows, doors and curtainwalls. As the Architect/Specifier, you are responsible for the performance and quality of the exterior façade components. Issues such as workmanship details and warranty concerns all necessitate field testing of your installed fenestration products.

Lab vs. Real World

Most all windows, doors and curtainwalls are tested in a laboratory environment. Industry standards and guidelines such as AAMA/WDMA/CSA 101/I.S.2/A440 and AAMA 501 are typical voluntary specifications to which fenestration manufacturers validate certain performance characteristics. As specifiers of critical performance characteristics, laboratory results and findings are crucial to the initial development and planning of a given structure. As the term would imply, laboratory testing is a controlled environment, which typically provides the " best case scenario " as it relates to the potential performance of a given system.
Manufacturers pay particular attention to detail in the production of laboratory test specimens. The same attention may not always apply to production units, which roll off the production line. An infinite number of variables interact with the production unit, which may have a tremendous impact to the primary performances. Machining tolerances, human interaction and production scheduling/capacities have a direct effect on the quality and performance of a given product.
Field verification/testing can identify certain concerns or deficiencies, which may have originated from the factory that are pertinent to the performance expected by the owner. If field checks are done early in the installation phase, remedial work can often times be performed to correct problems before they have an adverse effect on the building. Typically, it is more cost effective and convenient to remediate before the unit is installed. In the case of large projects, important quality issues can be addressed or handled before the entire shipment reaches the job site.

Verify the Installation

In a manner similar to the actual production of the fenestration, several variables of the installation can have a direct impact on the performance of a product. Manufacturers typically provide a procedure for proper installation of their product. Deviations from this methodology can cause serious problems. The deviations are not always related to the installer's ability to follow approved practices, but rather at times the problem may originate from changing jobsite conditions. In either case, the installation of the actual project-related units is no longer controlled in a manner similar to the laboratory test specimen.

Hedge Your Bets

As with any product or service specified, manufacturers and contractors are called upon to provide a statement of quality and performance warranty . Most specifications have a warranty clause. As a specifier, the warranty can provide two things. First, the warranty and performance requirements can provide a minimum level of quality which can prohibit unwanted manufacturers. If a manufacturer can not provide a product which meets the warranty requirements, you may not want their products on your project. Secondly, warranty clauses usually define stipulations which protect the owner against failures or " less than expected " performance. Failures can include excessive water leakage or air infiltration, condensation, excessive deflections, faulty operation and deterioration in excess of normal weathering. What better way to verify some of these concerns than field testing of your window, door and curtainwall installations?

Tuesday, February 17, 2009

March Forecast

Recon Independent Assessments is looking forward to what appears to be shaping up to be a busy month in March.

Testing will include several locations in south and central Florida. From post secondary school campus projects, a public transit facility, hospital expansions, and medical office space, our on site field testing of installed windows is in demand.

Savvy business owners and project managers recognize that by using Recon Independent Assessments, they are receiving the highest quality testing services available at a great value. Recon's owners are in the trenches leading the way by providing testing at rates that make the "big boys" blush.

Contact us today to get your project proposal. info@gorecon.net

ASTM E-1105 Field Testing by the best for much less. Compare and save.

Tuesday, January 27, 2009

Building Envelope Moisture Intrusion Testing and Installed Window Testing for Coastal Condominium

Recon Independent Assessments spent several days on-site conducting extensive testing to help determine the cause of multiple intrusion points along the Eastern elevation of the structure. A full report of testing results and observations was helpful in determining the correct remedial actions required to correct the water intrusion through the building envelope.























Recon Independent Assessments can help your team avoid moisture intrusion problems by providing field testing during the construction process. From mock-up testing to verification of installed products, Recon would like to be part of delivering a sustainable structure to the building owner. If you are an owner's rep that is looking for a consulting firm / testing agency to ensure your owner is getting a building that meets the design intent; contact us today for a proposal. We look forward to working with everyone, from the Architect to the Window Installers.











Wednesday, January 21, 2009

University of North Florida Student Union - Elkins Constructors

Recon Independent Assessments has spent the last three days in Jacksonville, FL providing field testing of installed windows and curtain wall. The ASTM E-1105 test method has been employed to evaluate the sample specimens.
Additional testing is scheduled to begin again soon.








Recon Independent Assessments is available to assist with field testing on your project. Contact us today for a proposal. We look forward to assisting you with any AAMA or ASTM protocol called for in the project specifications.